Higth Tecnology Nurse call System
Innovative and future-oriented features
The Alech4.0 calling system is available in some differents configurations, in order to satisfy any need in terms of costs and functionality, from the small department to the complete structure .
-
Central server or local mini server, infirmary station management unit with voice communication, call unit from the rooms which can then be wired BUS, ethernet or wireless and possibly also connected with other devices such as temperature sensors, humidity, corridor monitors, wireless receivers for staff, the system can also allow the location of the staff.
-
depending on the configuration chosen, it will be possible to know the operating status of each device in real time, it will be possible to carry out updates and maintenance assistance even remotely, it will be possible to add new devices, entire systems, other departments or entire hospitals, and it will be possible to integrate with the new IOT devices.
-
Ip technology also allows you to send alarms and messages to mobile phones, Voip phones, etc.
-
Mixed connection - Wireless beds + Wired system: in some situations it will be much more practical to have a mixed connection, so for example to connect the bedrooms and bathrooms with our two-way wireless keyboards that give the same reliability as the wired system with continuous connection and status control buttons. this will allow a streamlining of the installation of the devices throughout the room without the need for masonry work
-
Completely wireless connection: the whole system can also be designed in completely wireless mode, this obviously allows many advantages in terms of costs and installation times, especially if you want to replace an old existing system while the patients are still inside the hospital
Wired connection:
different solutions are available:
-
Operating principle of the bus system: The C-01ND room concentrator is the heart of the system and manages the operation of the whole room with Bus connection in full autonomy, including the outdoor lamp, in this way the system maintains its autonomy in any situation.
-
The concentrator has a display with OLED technology and an integrated light and acoustic signaling system compliant with VDE standards, this allows the staff to see the situation in the room in real time, the display of unanswered calls and alarm signals, presence management. If you place the concentrator outside the room, it will also be possible to do without the standard outdoor lamp. The concentrator C01-ND may have available connections BUS2 for connection to the ward concentrator, ethernet, rfid, wi-fi and Bluetooth for connecting to other devices.
-
Mixed connection - Wireless beds + Wired system: in some situations it will be much more practical to have a mixed connection, so for example to connect the bedrooms and bathrooms with our two-way wireless keyboards that give the same reliability as the wired system with continuous connection and status control buttons. this will allow a streamlining of the installation of the devices throughout the room without the need for masonry work
-
Completely wireless connection: the whole system can also be designed in completely wireless mode, this obviously allows many advantages in terms of costs and installation times, especially if you want to replace an old existing system while the patients are still inside the hospital
scarica la brochure
MT-00
-
MT-00 21 "monitor with integrated mini server
Department management: allows direct management of the department and the configuration of all
calls, historical recording and events.
Management of calls and taking charge of the patient call on a mobile phone with our APP.
It allows the monitoring of priority and historical calls, centralized management
of nursing calls within specific areas providing staff with the
view all alarms and events on a single screen and avoid waiting
to search for health professionals
MT-00
Microsoft Windows operating system
Integrated mini server, for the complete management of department or group of departments
Dimensions: 530mm x 340mm x 50mm
MT-01
-
MT-01 Monitor -mini Server
-
department management: allows direct management of the department without having to install expensive servers, it also allows the configuration of all calls,
-
Historical recording and events.
-
Call management and took charge of the patient call on mobile with our APP
-
In the work progress situation, everything can then also be subsequently connected to a central Server for the total management of the structure
-
Nurse monitor 14 inches
-
It allows the monitoring of priority and historical calls.
-
Allows centralized management of nursing calls within specific areas by providing staff to view all alarms and events on a single screen ed avoiding waiting for the search for health professionals
-
front camera of touch screen: capacitive touch screen
-
Display resolution: 1920x1080
-
3.5mm headphone socket with microphone Loudspeaker: 2 x 2w
-
Dimensions: length 349mm x width 112mm x height 239mm
MT-01B
14 "VOIP / SIP touch screen TERMINAL
It allows voice communication between voip terminals of the system, the reception of alarms, the management of all the programming functions of the department
hands-free communication or with telephone terminal
-
Historical recording and events.
-
Call management and took charge of the patient call on mobile with our APP
-
Management of voice calls from other devices connected to the local network located in the various rooms
-
It allows the monitoring of priority and historical calls.
-
Allows centralized management of nursing calls within specific areas by providing staff to view all alarms and events on a single screen and avoiding waiting for the search for health workers
-
Front camera of touch screen: capacitive touch screen
-
SPECIFICATIONS: - Front camera - Capacitive Touch Screen -
-
Display resolution: 1920x1080
-
- Speakers: 2 x 2w
-
- Dimensions: L 349mm x W 112mm x H 239mm
MT-02B
8 "touch screen room terminal
Voice functions with SIP / Voip protocol
Complete functionality for voice call management allows room calls with hands-free function for communication between staff and patients or staff and staff, wired or WI-FI connection with integrated telephone handset or hands-free mode.
Prepared for wall mounting or with desk bracket
Size: 200mm x 210mm x 70mm
C-03ND
Room terminal 7 "touch screen Voice functions with protocol sip / voip
4 addressable call keys + 8 addressable touch screen keys
allows room calls with hands-free function for communication between staff and patients or staff and staff
wired or wi-fi connection
- Touch screen
- WiFi (2.4G)
- LAN connection
- PoE (Power over ethernet).
- Built-in 2W speaker
MT-02 Monitor "21
Room terminal 4 "Voice functions with protocol sip / voip, 4 addressable call buttons
allows room calls with hands-free function for communication between staff and patients or staff and staff
wired or wi-fi connection
- Touch screen
- WiFi (2.4G)
- LAN connection
- PoE (Power over ethernet).
- Built-in 2W speaker
MT-02
21 ”digital wall monitor with call indication
in progress and those waiting, complete with bracket.
• Calls will change color and arrangement based on
to the set priority.
• Adaptive display based on the number of active calls
• Selection of ringtone volume level that can be set for day and night
• WI-FI or LAN connection
• Dimensions: 520mm x 340mm x 50mm
C-01ND
The C-01ND room concentrator is the heart of the system and manages the operation of the whole room with Bus connection in full autonomy, including the floor lamp, in this way the system maintains its autonomy in any situation.
The concentrator has a display with OLED technology and an integrated light and acoustic signaling system compliant with VDE 834 standards, this allows the staff to see the situation in the room in real time, the display of unanswered calls and alarm signals, presence management. If you place the concentrator outside the room, it will also be possible to do without the standard outdoor lamp
Connections BUS2 for connection to the ward concentrator, ethernet, rfid, wi-fi and Bluetooth for connecting to other devices.
Follow me function when in presence, this allows staff in the room to be notified of the call from other rooms
Monitor functionality : if set correctly, the device can also be used as a monitor to be inserted in the corridors of the infirmaries, etc.
BLE functionality: it allows to automatically detect the operator code inside the room
Room terminal with functions dedicated exclusively to the operator
Bus connections for bed unit, toilet unit and outdoor lamp.
Wall mount type, can be fixed on standard 3 module electrical box
All devices are with antimicrobial materials
• presence activation reset
• emergency call
• oled display
• connections for managing outdoor lamps
• Integrated alarm light with different colors. Acoustic alarm included
• "blue code" emergency call button
• Coated with antimicrobial products • Dimensions (L 115 * W 74 * H 21)
connettore RJ45
Luce Integrata
WL-01C
Terminal for bed with integrated night light and external light control
Wall mount type, can be wall mounted on a standard 3 module electrical box
functionality: Call, Reset, Presence, Emergency, integrated courtesy light, RJ45 connection for Patient Terminal PR-PL00 or PR-L01 working with smart lamp LT-01-ND, it does not require the C-01ND concentrator.
• Reset and Call buttons
• Integrated courtesy light
• Main light control on the patient terminal
• automatic release system with patient terminal disconnection alarm
• Reassurance LED on the patient terminal
• 04-wire bus connections
• Dimensions (L 115 * W 74 * H 21) (mm)
connettore RJ45
integrated ligth
WL-01
Terminal for bed with integrated night light and light control on keyboard and patient pendant keyboard
Wall mount type, can be wall mounted on a standard 3 module electrical box
functionality: Call, Reset, integrated courtesy light, RJ45 connection for PR-PL00 or PR-L01 Patient Terminal
working with concentrator C-01ND , .
• Reset and Call buttons
• Integrated courtesy light
• Light control
• automatic release system with patient terminal disconnection alarm
• Reassurance LED on the patient terminal
• 04-wire bus connections
• Dimensions (L 115 * W 74 * H 21) (mm)
WL-02
Terminal for bed with call and reset, integrated night light that can be controlled from the patient's pendant keyboard
Wall mount type, can be wall mounted on a standard 3 module electrical box
functionality: Call, Reset, integrated courtesy light, RJ45 connection for PR-PL00 or PR-L01 Patient Terminal
working with concentrator C-01ND , .
• Reset and Call buttons
• Integrated courtesy light
• Light control
• automatic release system with patient terminal disconnection alarm
• Reassurance LED on the patient terminal
• 04-wire bus connections
• Dimensions (L 115 * W 74 * H 21) (mm)
PR-L01
Patient terminal with call button and light control
Terminal in antibacterial silicone, luminescent button e patient reassurance led and lights control
Disconnection system if subjected to traction greater than 3 Kg
complete with support, clips for sheets and 3m cable
dimensions: 85 x 45 x 20 mm
luminescent call buttons
PR-L00
Patient terminal with call button
Terminal in antibacterial silicone, luminescent button e patient reassurance led.
Disconnection system if subjected to traction greater than 3 Kg
complete with support, clips for sheets and 3m cable
dimensions: 85 x 45 x 20 mm
TS-01
Generic terminal IP65 with call and reset, it can be used as a control terminal with bathroom tie rod
Wall mount type, can be wall mounted on a standard 3 module electrical box
functionality: Call, Reset, interfacing with external devices on / off
working with concentrator C-01ND , .
• Reset and Call buttons
• Reassurance LED on the patient terminal
• ON / OFF connection input
• 04-wire bus connections
• Dimensions (L 115 * W 74 * H 21) (mm)
TB-01
Pull cord Toilet terminal, IP65 grade with call and reset,
Wall mount type, can be wall mounted on a standard 3 module electrical box
functionality: Call, Reset, Bus connection
working with concentrator C-01ND ,
• Reset and Call buttons
• Reassurance LED on the patient terminal
• ON / OFF connection input
• 04-wire bus connections
• Dimensions (L 115 * W 74 * H 21) (mm)
LT-01
The outside door light signals the call set in different colors, colors used: Red, green, white and blue.
RGB LED technology, multicolored division into 3 sectors, complete with sound alarm
according to VDE-834 standards
direct connection to concentrator C-01ND
Size: 104 * 86 * 38
LT-01ND
The lamp out of town intelligent allows the management of all the devices connected inside the room, does not require the C-01ND room concentrator, signals the set call with different colors, colors used: Red, green, white and blue.
RGB LED technology, multicolored division into 3 sectors, complete with sound alarm
according to VDE-834 standards
Bus connection
Size: 104 * 86 * 38
LT-02D
The lamp autonomous out door , has three ON / OFF inputs and one Reset input.
By connecting ON / OFF signals it will be possible to activate the lamp without the need for other devices
It is possible to manage 3 alarm levels with three different colors and acoustic alarms
one input is used for general cancellation of the General alarm
colors used: Red, green, white and blue.
RGB LED technology, multicolored division into 3 sectors, complete with sound alarm
according to VDE-834 standards
Connection: wires on / off
5Vdc power supply or 110 / 220Vac adapter
Size: 104 * 86 * 38